HVAC System - Manual A/C - DTCS

MANUAL A/C DIAGNOSTIC TROUBLE CODE IDENTIFICATION

DTC No. System malfunction location Service Information
B1086:71 Airflow mode actuator motor lock (See DTC B1086:71 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .)
B10FB:71 Air intake actuator motor lock (See DTC B10FB:71 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .)
B11F0:12 Air intake actuator (potentiometer) circuit short to power supply (See DTC B11F0:12, B11F0:13 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .)
B11F0:13 Air intake actuator (potentiometer) circuit open
B11F5:86 Invalid data (humidity sensor temperature) received from humidity sensor (See DTC B11F5:86, B1A69:86, U210A:86 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .)
B13AA:71 Air mix actuator motor lock (See DTC B13AA:71 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .)
B13AB:12 Air mix actuator (potentiometer) circuit short to power supply (See DTC B13AB:12, B13AB:13 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .)
B13AB:13 Air mix actuator (potentiometer) circuit open
B1A69:86 Invalid data (relative humidity) received from humidity sensor (See DTC B11F5:86, B1A69:86, U210A:86 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .)
B1B71:11 Evaporator temperature sensor circuit short to ground (See DTC B1B71:11, B1B71:13 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .)
B1B71:13 Evaporator temperature sensor circuit open
B1C1C:12 Airflow mode actuator (potentiometer) circuit short to power supply (See DTC B1C1C:12, B1C1C:13 [MANUAL AIR CONDITIONER] .)
B1C1C:13 Airflow mode actuator (potentiometer) circuit open
U0010:88 Unit communication error (MS-CAN) (See DTC U0010:88, U0155:00 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .)
U0155:00 Communication error with instrument cluster
U0423:68 Invalid date received from Instrument cluster (See DTC U0423:68 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .)
U200D:11 Climate control unit circuit voltage (+5V) circuit short to ground (See DTC U200D:11 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .)
U210A:86 Invalid data (windshield temperature) received from humidity sensor (See DTC B11F5:86, B1A69:86, U210A:86 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .)
U2300:54 Configuration error (data not received) (See DTC U2300:54, U2300:55, U2300:56, U2300:64 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .)
U2300:55 Configuration error (not configured)
U2300:56 Configuration error (ineffective/no n-interchangeable data read)
U2300:64 Configuration error (error value read)
U3003:16 Climate control unit power supply circuit voltage below threshold (10 V or less) (See DTC U3003:16, U3003:17 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .)
U3003:17 Climate control unit power supply circuit voltage above threshold (17.3 V or more)
U300E:13 Climate control unit power supply circuit open (IG2) (See DTC U300E:13 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .)