Illumination Light Inspection
- Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
- Apply battery voltage to TCS OFF switch terminal L, and connect terminal K to ground.
- Verify that the LED illuminates.
- If there is any malfunction, replace the TCS OFF switch.