Selector Cable Adjustment
- Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
- Remove the following parts:
- Selector lever knob (See SELECTOR LEVER REMOVAL/INSTALLATION .)
- Shift panel (See SHIFT PANEL REMOVAL/INSTALLATION .)
- Shift the selector lever to the P position.
- Pull out the safety lock in the direction of the arrow
- shown in the figure, pull out the lock piece in the direction of the arrow
- shown in the figure, and release the lock. (See Selector Cable (Selector Lever Side) Installation Note .)
- Set the manual shaft to the P position.
- Press in the lock piece in the direction of the arrow
- shown in the figure, press in the safety lock in the direction of the arrow
- shown in the figure, and lock it.
- Perform the procedure in the reverse order of Step 1 to 5 to install the removed part.
- Perform the selector lever inspection. (See SELECTOR LEVER INSPECTION .)