PID/Data Monitor Table (Position Memory Control Module)

-: Not applicable

PID Unit/Operation Data Contents Module Control Terminal
FTLT_MTR_DN Off/On
  • Off: Tilt motor is not operated to down.
  • On: Tilt motor is operated to down.
3D (Tilt motor output (down))
FTLT_MTR_UP Off/On
  • Off: Tilt motor is not operated to up.
  • On: Tilt motor is operated to up.
3D (Tilt motor output (up))
FTLT_SW_DN Off:
  • Off: Tilt switch is not in down.
  • On: Tilt switch is in down.
2D (Tilt switch input (down))
FTLT_SW_UP Off/On
  • Off: Tilt switch is not in up.
  • On: Tilt switch is in up.
2C (Tilt switch input (up))
M_SET_SW Off/On
  • Off: Position memory switch SET not presseD
  • On: Position memory switch SET pressed
2K (Set switch input)
MEMORY_SW_1 Off/On
  • Off: Position memory switch 1 not presseD
  • On: Position memory switch 1 pressed
2L (Memory switch 1 input)
MEMORY_SW_2 Off/On
  • Off: Position memory switch 2 not presseD
  • On: Position memory switch 2 pressed
2M (Memory switch 2 input)
MEMORY_SW_3 Off/On  
NOTE:
  • Displays in the M-MDS but it does not operate.
REC_MTR_BK Off/On
  • Off: Recliner motor is not operated to back.
  • On: Recliner motor is operated to back.
3H (Recliner motor output (backward))
REC_MTR_FW Off/On
  • Off: Recliner motor is not operated to front.
  • On: Recliner motor is operated to front.
3G (Recliner motor output (forward))
REC_SW_DWN Off/On
  • Off: Recliner switch is not in back.
  • Off: Recliner switch is in back.
2H (Recliner switch input (backward))
REC_SW_UP Off/On
  • Off: Recliner switch is not in front.
  • On: Recliner switch is in front.
2G (Recliner switch input (forward))
RTLT_MTR_DN Off/On
  • Off: Lift motor is not operated to down.
  • On: Lift motor is operated to down
3F (Lift motor output (down))
RTLT_MTR_UP Off/On
  • Off: Lift motor is not operated to up.
  • On: Lift motor is operated to up.
3E (Lift motor output (up))
RTLT_SW_DN Off/On
  • Off: Lift switch is not in down.
  • On: Lift switch is in down.
2F (Lift switch input (down))
RTLT_SW_UP Off/On
  • Off: Lift switch is not in up.
  • On: Lift switch is in up.
2E (Lift switch input (up))
SLIDE_MTR_B Off/On
  • Slide motor is not operated to back.
  • On: Slide motor is operated to back.
3B (Slide motor output (backward))
SLIDE_MTR_F Off/On
  • Off: Slide motor is not operated to front.
  • On: Slide motor is operated to front.
3A (Slide motor output (forward))
SLIDE_SW_B Off/On
  • Off: Slide switch is not in back.
  • On: Slide switch is in back.
2B (Slide switch input (backward))
SLIDE_SW_F Off/On
  • Off: Slide switch is not in front.
  • On: Slide switch is in front.
2A (Slide switch input (forward))
VPWR V Displays the position memory control module power supply voltage. 1M (Power supply)