Indicator Inspection
NOTE:
- The indicator is integrated with the shift panel.
- Remove the shift panel. (See SHIFT PANEL REMOVAL/INSTALLATION .)
- Verify that the voltages of each of the terminals are as indicated in the terminal voltage table (reference).
- If the voltage is not as specified in the terminal voltage table (reference), inspect the parts under Inspection item(s) and related wiring harnesses.
- If the inspection items are normal, replace the shift panel. (See SHIFT PANEL REMOVAL/INSTALLATION .)
Terminal Voltage Table (Reference)
-: Not applicable
TERMINAL VOLTAGE REFERENCE
| Terminal | Connected to | Test condition | Voltage (V) | Inspection item(s) |
|---|---|---|---|---|
| A | Battery | Under any condition | B+ |
|
| B | IG1 relay No. 2 | Ignition is switched ON | B+ |
|
| Except above | Below 1.0 | |||
| C | Selector lever component (shift-lock solenoid) | The following conditions are met (except emergency manual shift-lock release system is operated)
|
Below 1.0 |
|
| Except above | B+ | |||
| D | - | - | - | - |
| E | CAN module | This terminal is used for communication and cannot be used for malfunction determination during terminal voltage inspection. Perform a DTC inspection. | ||
| F | CAN module | This terminal is used for communication and cannot be used for malfunction determination during terminal voltage inspection. Perform a DTC inspection. | ||
| G | Selector lever component (up switch) | Selector lever is in the M position (+) side position. | Below 1.0 |
|
| Selector lever is not in the M position (+) side position. | B+ | |||
| H | Selector lever component (down switch) | Selector lever is in the M position (-) side position. | Below 1.0 |
|
| Selector lever is not in the M position (-) side position. | B+ | |||
| I | Selector lever component (M position switch) | Selector lever is in the M position. | Below 1.0 |
|
| Selector lever is not in the M position. | B+ | |||
| J | Ground point | Under any condition | Approx. 0 |
|