Selector Cable Adjustment: Notes
- Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
- Remove the following parts:
- Selector lever knob (See SELECTOR LEVER COMPONENT REMOVAL/INSTALLATION .)
- Shift panel (See SHIFT PANEL REMOVAL/INSTALLATION .)
- Shift the selector lever to the P position.
- Pull out the safety lock in the direction of the arrow (1) shown in the illustration, pull out the lock piece in the direction of the arrow (2) shown in the illustration, and release the lock. (See SELECTOR CABLE (SELECTOR LEVER SIDE) INSTALLATION NOTE .)
- Set the manual shaft to the P position.
- Press in the lock piece in the direction of the arrow (1) shown in the illustration, press in the safety lock in the direction of the arrow (2) shown in the illustration, and lock it.
- Perform the procedure in the reverse order of Step 1 to 5 to install the removed part.
- Perform the selector lever inspection. (See SELECTOR LEVER INSPECTION .)