Without using M-MDS
- Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION .)
- Remove the fuel pump relay.CAUTION:
- Short the specified terminals because shorting the wrong terminal of the relay and fuse block may cause malfunctions.
- Using a jumper wire, short fuel pump relay terminals C and D in the relay and fuse block.
- Connect the negative cable and operate the fuel pump. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION .)
- Verify that there is no fuel leakage from the pressurized parts.
Standard
There shall be no leakage after 5 min.
- In the case of fuel leakage, replace the following components and then recheck using the fuel leakage checking procedure.
- If there is leakage, replace the fuel hoses and clips.
- If there is damage on the seal on the fuel pipe side, replace the fuel pipe.