CAUTION:
  • Disconnecting/connecting the quick release connector without cleaning it may possibly cause damage to the fuel pipe and quick release connector. Always clean the quick release connector joint area before disconnecting/connecting using cloth or soft brush, and make sure that it is free of foreign material.
  1. Complete the "BEFORE SERVICE PRECAUTION". (See BEFORE SERVICE PRECAUTION .)
  2. Disconnect the quick release connector as shown in the figure. (See QUICK RELEASE CONNECTOR REMOVAL/INSTALLATION .)
    G11436893Courtesy of MAZDA MOTORS CORP.
  3. Connect a long hose to the disconnected quick release connector and drain the fuel into a container used for collecting gasoline.
  4. Drain the fuel from the fuel tank using the following procedure:
    CAUTION:
    • The fuel pump could be damaged if it is operated while there is no fuel in the fuel tank. Verify the amount of fuel being discharged from the hose and stop operation of the fuel pump when essentially no fuel is being discharged.

    Using M-MDS 

    1. Connect the M-MDS to the DLC-2.
    2. Using the simulation function "FP", start the fuel pump. (See ON-BOARD DIAGNOSTIC TEST .)

    Without using M-MDS 

    1. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION .)
    2. Remove the fuel pump relay.
      G11436894Courtesy of MAZDA MOTORS CORP.
      CAUTION:
      • Short the specified terminals because shorting the wrong terminal of the relay and fuse block may cause malfunctions.
    3. Using a jumper wire, short fuel pump relay terminals C and D in the relay and fuse block.
      G11436895Courtesy of MAZDA MOTORS CORP.
    4. Connect the negative battery cable and operate the fuel pump. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION .)
  5. Stop the fuel pump using the following procedure.

    Using M-MDS 

    1. Using the simulation function "FP", stop the fuel pump. (See ON-BOARD DIAGNOSTIC TEST .)
    2. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION .)

    Without using M-MDS 

    1. Remove the jumper wire to stop the fuel pump.