Shift-Lock Solenoid Inspection: Standard
TERMINAL VOLTAGE SPECIFICATIONS - STANDARD
| Terminal | Connected to | Test condition | Voltage (V) |
|---|---|---|---|
| A | IG1 relay No. 2 | Ignition switched ON (engine on) | B+ |
| Except above | Below 1.0 | ||
| E | Shift panel indicator | The following conditions are met (except emergency manual shift-lock release system is operated)
|
Below 1.0 |
| Except above | B+ |
- If the voltage is not as indicated in the table, repair or replace the related wiring harness.
- If the related wiring harnesses are normal, replace the selector lever component. (See SELECTOR LEVER COMPONENT REMOVAL/INSTALLATION .)