Function Inspection
- Connect the M-MDS to the DLC-2.
- Switch the ignition ON (engine off).
- Display the PIDs TP1 and TP2. (See PID/DATA MONITOR INSPECTION .)
- Compare the voltage and opening angle indications for the PIDs TP1 and TP2 with the standard in the table indicated below.
- If they do not match the standard, perform the voltage inspection. (See VOLTAGE INSPECTION .)
STANDARD SPECIFICATION
| Condition | TP1 | TP2 | ||
|---|---|---|---|---|
| V | % | V | % | |
| Accelerator pedal released | Approx. 1.10 | Approx. 21.96 | Approx. 3.89 | Approx. 22.35 |
| Accelerator pedal depressed | Approx. 4.59 | Approx. 81.76 | Approx. 0.42 | Approx. 91.37 |