RECIRCULATION Air Control
Air recirculating valve is opened or closed depending on input signal to EDS control unit to improve burn-up conditions in trap oxidizer. When air recirculating valve closes, vacuum of 30 Bar remains on valve. Air recirculating valve opens when engine speed is between 1200-3600 RPM and fuel rack load is less than .35" (9 mm).