Understanding Diagnostic Information: Notes
For reading and understanding fault code diagnosis, as an example, using DIAGNOSTIC TESTS, read 2 under IMPULSE READOUT column. Read step 2.0 under TEST STEP/TEST SCOPE column. Component being tested is fuel rack position sensor (L7). Under TEST CONNECTION column, using DVOM, measure resistance between contact box (N39) terminals No. 4 and 5. Under TEST CONDITION column, make measurement with ignition off and EDS control unit disconnected. Resistance is 46-54 ohms under NOMINAL VALUE column. If resistance is not within specification, follow instructions under POSSIBLE CAUSE/REMEDY column.
Using one other example, read 2 under IMPULSE READOUT column. Read step 2.1 under TEST STEP/TEST SCOPE column. Component being tested is fuel rack position sensor (L7). Under TEST CONNECTION column, using DVOM, measure resistance between fuel rack position sensor (L7) terminals No. 2 and 3. Under TEST CONDITION column, make measurement with ignition off and fuel rack position sensor connector disconnected. Resistance is 46-54 ohms under NOMINAL VALUE column. If resistance is not within specification, follow instructions under POSSIBLE CAUSE/REMEDY column.