Diagnostic Trouble Code Memory (Section 11)
NOTE:
Connect impulse counter scan tool as follows:
- Red wire to socket 3.
- Black wire to socket 1.
- Yellow wire to Diagnostic Module (socket 19), Base Module (socket 8), Left LH-SFI Control Module (socket 5), Right LH-SFI Control Module (socket 4), Left Ignition Control Module (socket 18), Right Ignition Control Module (socket 17) and EA/CC/ISC Control Module (socket 7).
- Connect the impulse counter scan tool and adapter for impulse counter scan tool to diagnostic connector (X11/4). See Figure .