Test 1: Circuits 30E & 31E
- Using Harness Adapter (210 589 01 63 00), connect Breakout Box (129 589 00 21 00) to combination control module. Measure voltage between terminals No. 61 and 75 at breakout box. If battery voltage exists, go to next step. If battery voltage does not exist, repair wiring.
- Measure voltage between ground and terminal No. 75 at breakout box. If battery voltage exists, circuits 30E and 31E are okay at this time. If battery voltage does not exist, repair wiring.