DIAGNOSTIC TROUBLE CODE LIST (PSE CONTROL MODULE)

Code Cause Test/Remedy
B1021 No Communication With PSE Control Module Replace CCM, Replace PSE Control Module

Perform PSE control module test. See PNEUMATIC SYSTEM EQUIPMENT under SYSTEM TESTS.

B1024 No Communication With CCM (Low) Replace CCM

Perform PSE control module test steps 2), 4), 6) & 8). See PNEUMATIC SYSTEM EQUIPMENT under SYSTEM TESTS.

B1025 No Communication With CCM (High) Replace CCM

Perform PSE control module test steps 3), 5), 7) & 8). See PNEUMATIC SYSTEM EQUIPMENT under SYSTEM TESTS.

B1100 Lock Sw. Short Between RCL Control Module & CCM

Perform remote control locking system test steps 19 and 20). See REMOTE CONTROL LOCKING (RCL) under SYSTEM TESTS in KEYLESS ENTRY SYSTEM article.

B1116 RHR Unlocking Switch Signal More Than 25 Seconds

Perform retractable rear headrest test. See RETRACTABLE REAR HEADREST under SYSTEM TESTS.

B1117 Interior Switch Signal More Than 25 Seconds

Perform central locking test step 1). See CENTRAL LOCKING under SYSTEM TESTS.

B1124 Remote Trunk Release Signal More Than 25 Seconds

Perform remote trunk release test step 1). See REMOTE TRUNK RELEASE under SYSTEM TESTS.

B1436 Central Locking (Malfunction Due To Error Signal From Other Consumers or Pneumatic System Leak)

Perform pneumatic system vacuum test steps 1) through 9). See PNEUMATIC SYSTEM EQUIPMENT under VACUUM SYSTEM TESTS.

Perform central locking vacuum test steps 1) through 8). See CENTRAL LOCKING under VACUUM SYSTEM TESTS.

B1437 Retractable Headrest Pneumatic System Leak

Perform retractable rear headrest vacuum test step 1) through 3). See RETRACTABLE REAR HEADREST under VACUUM SYSTEM TESTS.

B1438 Multi-Contour Seat (Air Pressure Or Safety Time)

Perform orthopedic seat vacuum test steps 1) through 4). See ORTHOPEDIC SEAT under VACUUM SYSTEM TESTS.

B1439 Manifold Vacuum Assist Time Greater Than Maximum

Perform manifold vacuum assist test. See MANIFOLD VACUUM ASSIST under VACUUM SYSTEM TESTS.