Fuel Injector Tests: Notes
NOTE:
When performing test procedures, connect jumper wire at appropriate ME-SFI control module connector. If testing fuel injectors No. 1-6, jumper right cylinder bank ME-SFI control module (N3/12) connector. If testing fuel injectors No. 7-12, jumper left cylinder bank ME-SFI control module (N3/11) connector.