Test Procedure
- Voltage -
Connect DVOM between ME-SFI control module connector "E" terminals No. 48 and 45 (socket box terminals No. 104 and 101). Turn ignition on. Voltage should correspond with temperature. See INTAKE AIR TEMPERATURE SENSOR VOLTAGE
table. If voltage is okay, test is complete. If voltage is not okay, perform remaining step. Possible causes are defective ME-SFI control module (N3/10).INTAKE AIR TEMPERATURE SENSOR VOLTAGE
Temperature (1) Volts 50°F (10°C) 3.1 68°F (20°C) 2.7 86°F (30°C) 2.2 104°F (40°C) 1.8 122°F (50°C) 1.4 140°F (60°C) 1.1 (1) Voltage values can vary plus or minus 5 percent. - Resistance -
Turn ignition off. Connect DVOM between ME-SFI control module connector "E" terminals No. 48 and 45 (socket box terminals No. 104 and 101). Resistance should correspond with temperature. See INTAKE AIR TEMPERATURE SENSOR RESISTANCE
table. If resistance is okay, test is complete. If resistance is not okay, possible causes are wiring harness failure or defective hot film MAF sensor (B2/5). Repair as necessary.INTAKE AIR TEMPERATURE SENSOR RESISTANCE
Temperature (1) Ohms 50°F (10°C) 3600 68°F (20°C) 2420 86°F (30°C) 1660 104°F (40°C) 1170 122°F (50°C) 850 140°F (60°C) 600 (1) Resistance values can vary plus or minus 5 percent.