Generator Output

WARNING: This page does not describe the selected car, but rather 29 other vehicles, including the 2000 Mercedes-Benz SLK230, 2000 Mercedes-Benz SL500, 2000 Mercedes-Benz S500, 2000 Mercedes-Benz S430, and 2000 Mercedes-Benz ML55. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ensure connections at battery and generator are clean and tight. Ensure generator, engine and body are properly grounded. Ensure generator drive belt is properly adjusted and in good condition.
  2. Connect load tester/ammeter as per tester manufacturer's instructions. Connect voltmeter leads to battery terminals. Start engine and run at 3000 RPM. Adjust load tester to obtain maximum generator output. DO NOT allow voltage to drop to less than 12.7 volts.
  3. Maximum generator output should be within a few amps of generator rated output stamped on generator. If output is not within a few amps of generator rated output, replace voltage regulator and retest. If output is still low, repair or replace generator.