Left Cylinder Bank ME-SFI Control Module (N3/11)
Connect DVOM between left cylinder bank ME-SFI control module (N3/11) connector 1 terminals No. 45 and 25 (socket box terminals No. 45 and 25). Turn ignition on. Voltage should be 11-14 volts. If voltage is within specification, test is complete. If voltage is not within specification, possible cause is wiring harness failure. Repair as necessary.