| 01 |
91 |
11 |
0.0 |
0.0 |
2.5 |
s |
Oxygen Sensor Monitor Bank 1 - Sensor 1 |
| 01 |
92 |
11 |
0.4 |
0.0 |
39935 |
s |
Oxygen Sensor Monitor Bank 1 - Sensor 1 |
| 01 |
93 |
11 |
0.4 |
0.0 |
3.0 |
s |
Oxygen Sensor Monitor Bank 1 - Sensor 1 |
| 01 |
83 |
30 |
9062320 |
339970 |
515.397857 |
% |
Oxygen Sensor Monitor Bank 1 - Sensor 1 |
| 02 |
92 |
11 |
0.5 |
0.0 |
4.4 |
s |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 02 |
93 |
11 |
39904 |
0.0 |
4.4 |
s |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 02 |
D1 |
84 |
0.010 |
-32768 |
0.500 |
|
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 02 |
D2 |
11 |
0.0 |
0.0 |
200.0 |
s |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 02 |
83 |
30 |
20370765 |
16998526 |
32.762599 |
% |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 02 |
D4 |
81 |
7 |
-32768 |
50 |
|
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 02 |
D5 |
81 |
9 |
-30327 |
67 |
|
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 02 |
D6 |
86 |
0.000000 |
-9999811 |
0.000000 |
|
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 02 |
D7 |
86 |
0.000000 |
0.000000 |
9.999505 |
|
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 03 |
D1 |
84 |
0.010 |
-32768 |
0.500 |
|
Oxygen Sensor Monitor Bank 1 - Sensor 3 |
| 03 |
D2 |
11 |
0.0 |
0.0 |
200.0 |
s |
Oxygen Sensor Monitor Bank 1 - Sensor 3 |
| 03 |
83 |
30 |
20349402 |
16998526 |
32.762599 |
% |
Oxygen Sensor Monitor Bank 1 - Sensor 3 |
| 03 |
D4 |
81 |
-13 |
-32768 |
40 |
|
Oxygen Sensor Monitor Bank 1 - Sensor 3 |
| 03 |
D5 |
81 |
-13 |
-30 |
32767 |
|
Oxygen Sensor Monitor Bank 1 - Sensor 3 |
| 03 |
D8 |
1 |
37 |
0 |
32767 |
|
Oxygen Sensor Monitor Bank 1 - Sensor 3 |
| 21 |
90 |
6 |
0.000000 |
0.000000 |
0.000000 |
|
Catalyst Monitor Bank 1 |
| 31 |
97 |
6 |
0.740342 |
0.300287 |
19.999316 |
|
AGR-Monitor Bank 1 |
| 31 |
98 |
AF |
0.16 |
-327.68 |
3.50 |
% |
AGR-Monitor Bank 1 |
| 31 |
99 |
AF |
0.10 |
-327.68 |
5.50 |
% |
AGR-Monitor Bank 1 |
| 41 |
81 |
8B |
0.002 |
-32768 |
0.065 |
V |
Oxygen Sensor Heater Monitor Bank 1 - Sensor 1 |
| 81 |
A1 |
1 |
380 |
276 |
564 |
|
Fuel System Monitor Bank 1 |
| 81 |
A2 |
1 |
409 |
276 |
564 |
|
Fuel System Monitor Bank 1 |
| 81 |
A3 |
1 |
397 |
276 |
564 |
|
Fuel System Monitor Bank 1 |
| 81 |
A4 |
1 |
404 |
276 |
564 |
|
Fuel System Monitor Bank 1 |
| 81 |
A5 |
1 |
397 |
276 |
564 |
|
Fuel System Monitor Bank 1 |
| 81 |
A6 |
1 |
389 |
276 |
564 |
|
Fuel System Monitor Bank 1 |
| 85 |
98 |
30 |
2856485 |
0.891126 |
99.999856 |
% |
Charging Pressure Actuator Monitor Bank 1 |
| 85 |
97 |
6 |
0.906660 |
0.400078 |
19.999316 |
|
Charging Pressure Actuator Monitor Bank 1 |
| 98 |
85 |
4 |
0.000 |
0.400 |
65535 |
|
NOx-Catalyst Monitor Bank 1 |
| 98 |
B1 |
3 |
0.95 |
0.50 |
1.50 |
|
NOx-Catalyst Monitor Bank 1 |
| A2 |
0B |
24 |
0 |
0 |
65535 |
Counts |
Mis-Fire Cylinder 1 Data |
| A2 |
0C |
24 |
0 |
0 |
65535 |
Counts |
Mis-Fire Cylinder 1 Data |
| A3 |
0B |
24 |
0 |
0 |
65535 |
Counts |
Mis-Fire Cylinder 2 Data |
| A3 |
0C |
24 |
0 |
0 |
65535 |
Counts |
Mis-Fire Cylinder 2 Data |
| A4 |
0B |
24 |
0 |
0 |
65535 |
Counts |
Mis-Fire Cylinder 3 Data |
| A4 |
0C |
24 |
0 |
0 |
65535 |
Counts |
Mis-Fire Cylinder 3 Data |
| A5 |
0B |
24 |
0 |
0 |
65535 |
Counts |
Mis-Fire Cylinder 4 Data |
| A5 |
0C |
24 |
0 |
0 |
65535 |
Counts |
Mis-Fire Cylinder 4 Data |
| A6 |
0B |
24 |
0 |
0 |
65535 |
Counts |
Mis-Fire Cylinder 5 Data |
| A6 |
0C |
24 |
0 |
0 |
65535 |
Counts |
Mis-Fire Cylinder 5 Data |
| A7 |
0B |
24 |
0 |
0 |
65535 |
Counts |
Mis-Fire Cylinder 6 Data |
| A7 |
0C |
24 |
0 |
0 |
65535 |
Counts |
Mis-Fire Cylinder 6 Data |
| B2 |
85 |
17 |
27.70 |
5.70 |
655.35 |
kPa |
Diesel Particulate Filter Monitor Bank 1 |
| B2 |
C1 |
17 |
0.00 |
0.00 |
0.00 |
kPa |
Diesel Particulate Filter Monitor Bank 1 |
| B2 |
C3 |
36 |
0.00 |
0.00 |
0.00 |
g |
Diesel Particulate Filter Monitor Bank 1 |
| B2 |
C4 |
36 |
0.00 |
0.00 |
0.00 |
g |
Diesel Particulate Filter Monitor Bank 1 |