LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercedes Benz >> 2008 >> CL63 >> Repair and Diagnosis >> Engine Performance >> Ignition System >> Mixture Formation -- Cl63 >> Basic Knowledge >> ME-SFI alternator interface function - GF07.61-P-3003MAS
April 5, 2026: LEMON Manuals is launched! Read the announcement.

ME-SFI alternator interface function - GF07.61-P-3003MAS

ENGINES 156.984 in MODEL 216.377, 221.077 /177 as of Model Year 09 /AEJ 08 

Function requirements for the alternator interface, general points 

Alternator interface, general points 

Through the alternator interface, messages are exchanged over the drive LIN (LIN C1) between the alternator (G2) and the ME-SFI control unit (N3/10), in order to regulate the alternator control response. For this purpose, the ME-SFI control unit reads the following sensor and signal:

Alternator interface function sequence 

The ME-SFI control unit controls the alternator control response, for example, in order to reduce the regulation voltage (charging voltage) when the engine is at idle and the on-board electrical system battery is sufficiently charged This reduces the engine load, thus also reducing fuel consumption and improving the exhaust gas emissions.

The ME-SFI control unit controls the following functions:

The alternator constantly performs self-diagnosis and sends the results when requested to the ME-SFI [ME] control unit. The control unit compares the results with other signals (for example, engine rpm, on-board electrical system battery voltage, time since engine start) and thus detects any alternator faults.

The following faults are identified:

IMPORTANT Diagnosis

To check the regulation voltage, the on-board electrical system battery must be loaded with a battery tester, as the regulation voltage can be significantly reduced when the on-board electrical system battery is under full or no load.

IMPORTANT "Terminal 61 signal"

For alternators with an alternator interface, line "terminal 61" is not needed. From information which the ME-SFI [ME] control unit receives via the alternator interface, the "terminal 61 signal" is simulated in the ME-SFI [ME] control unit and is emitted via an output stage switching to ground (e.g. for the instrument cluster).

REFER TO SYSTEM WIRING DIAGRAMS Electrical function schematic, alternator interface ME Model 216 PE07.61-P-2755-97CAC
Model 221 PE07.61-P-2755-97SAC
  ME-SFI [ME] control unit, component description N3/10 GF07.61-P-6000MAS