LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercedes Benz >> 2009 >> CL63 >> Repair and Diagnosis >> Engine Performance >> Ignition System >> Mixture Formation -- Cl63 >> Basic Knowledge >> ME-SFI idle speed control function - GF07.61-P-2008MAS
April 5, 2026: LEMON Manuals is launched! Read the announcement.

ME-SFI idle speed control function - GF07.61-P-2008MAS

ENGINES 156.984 in MODEL 216.377, 221.077 /177 as of Model Year 09 /AEJ 08 

Idle speed control function requirements, general 

Idle speed control, general 

The idle speed control regulates and stabilizes the idle speed according to operating conditions and engine load.

For the idle speed control, the ME-SFI control unit (N3/10) reads the following sensors and signals:

Idle speed control function sequence 

The ME-SFI control unit regulates the idle speed through the front and rear throttle valve actuators (M16/3, M16/4) and adapts the injection time of the fuel injection valves (Y62) according to variations in the air mass.

To assist the idle speed control, the ME-SFI control unit can adjust the ignition angles of the ignition coils (T1) by up to 36° CKA ( ranK ngle) towards "retard" or 20° CKA toward "advance".

IMPORTANT Adjusting the ignition angle enables a faster response than adjusting the throttle valves.

The ME-SFI control unit regulates the idle speed in the following operating and engine load conditions:

Warm-up phase function sequence 

In the warm-up phase, the ME-SFI control unit controls the idle speed according to coolant temperature, in order to bring the catalytic converters more quickly up to operating temperature after engine start.

Additional function requirements in the warm-up phase are:

The ME-SFI control unit raises the idle speed to about 1100 to 1300 rpm for about 20 s.

After this time has elapsed, the idle speed is increased at a coolant temperature of < 70°C in line with the temperature for approx. 50 seconds by approx. 50 to 100 rpm.

Gear range selection "D" or "R" function sequence 

When gear range "D" or "R" is engaged, a lower idle speed is set in order to reduce the tendency of the vehicle to creep forward. To do this, the ME-SFI control unit evaluates the "gear range engaged" CAN signal from the electric controller unit (VGS).

Refrigerant compressor cut-in function sequence 

So that the engine idle speed will not fall when the refrigerant compressor is switched on, the AAC control unit first sends a status signal to the ME-SFI control unit.

The ME-SFI [ME] control unit adapts the idle speed appropriately.

Undervoltage in on-board electrical system battery function sequence 

If the ME-SFI control unit detects an undervoltage through "circuit 30", the idle speed is raised by about 100 rpm when gear range "D" or "R" is selected, until the ignition is switched off.

Purging function sequence 

The idle speed control prevents any change in the engine speed due to purging.

IMPORTANT Diagnosis

The basic setting of the idle speed can be read out and adjusted with the Diagnosis Assistance System (DAS.

REFER TO SYSTEM WIRING DIAGRAMS Electrical function schematic, ME-SFI idle speed control Model 216 PE07.61-P-2792-97CAC
Model 221 PE07.61-P-2792-97SAC
  ME-SFI [ME] control unit, component description N3/10 GF07.61-P-6000MAS