LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercedes Benz >> 2017 >> GLS63 AMG >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Electrical Drive System - 166 Chassis >> Basic Knowledge >> Automatic Engine Stop, Function - GF08.30-P-3001GRH
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Automatic Engine Stop, Function - GF08.30-P-3001GRH

ENGINE 276.821 in MODEL 166 

IMPORTANT The subfunction "automatic engine stop function" is considered and described from the point of view of the hybrid drive system.

We will not go into more detail here about internal signals and function sequences of the internal combustion engine and the A/T.

Function requirements for an automatic engine stop - general points 

IMPORTANT The automatic engine stop in hybrid vehicles is equivalent to electrical driving.

Automatic engine stop - general points 

An automatic engine stop is initiated if this is meaningful as part of the system optimization and the requested drive torque can be generated purely electrically. When an automatic engine stop occurs, the internal combustion engine is switched off by the ME-SFI [ME] control unit (N3/10) without switching off circuit 15.

The following listed read in signals are just related to the release for the automatic engine stop from external systems such as:

The ME-SFI [ME] control unit reads in the following signals for release of the automatic engine stop:

IMPORTANT If the internal combustion engine is off (e.g. automatic engine stop), the oil supply for the A/T is secured over the electrical auxiliary oil pump.

IMPORTANT If the internal combustion engine is off (e.g. automatic engine stop), the fuel supply is influenced appropriately over the FSCU (N118).

IMPORTANT If the automatic start/stop intervals exceed an established number in a certain time, the automatic engine stop is suppressed for a certain period of time.

Function sequence of an automatic engine stop 

The ME-SFI [ME] control unit continuously performs a system diagnosis and assesses the function requirements for an automatic engine stop.

The status of the electric auxiliary oil pump is checked before triggering of the automatic engine stop and then immediately actuated or actuated during triggering of the automatic engine stop by the fully integrated transmission control unit. The electric auxiliary oil pump secures the hydraulic system's oil supply in the automatic transmission when the internal combustion engine is switched off.

The internal combustion engine is switched off by the ME-SFI [ME] control unit if certain internal combustion engine conditions are fulfilled and all of the following conditions and releases have been awarded:

The ME-SFI [ME] control unit sends the request via the CAN network to the fully integrated transmission control unit for actuation of the wet clutch in order to disconnect the internal combustion engine from the drive. After appropriate feedback the ME-SFI [ME] control unit switches the internal combustion engine off over the opened wet clutch.

If during the automatic engine stop a release is retracted or a prerequisite is no longer fulfilled, the internal combustion engine will automatically be started without any defined action on the part of the driver.

If during the automatic engine stop a release is retracted or a prerequisite is no longer fulfilled, the internal combustion engine will automatically be started without any defined action on the part of the driver.

  Electrical function schematic for automatic engine stop   PE08.30-P-2053-97NAH 
  Overview of system components, hybrid drive system   GF08.30-P-9999GRH