LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercedes Benz >> 2021 >> C300 Base, 2D Convertible >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Mixture Formation - 205 Chassis >> Basic Knowledge >> Starting, Function - GF07.10-P-1001MRS
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Starting, Function - GF07.10-P-1001MRS

Engine 264.9 in Model 205, 253 

Function requirements, general 

IMPORTANT The fully integrated transmission control unit (Y3/8n4) transmits information about the engaged gear range via the drive train CAN (CAN C1) to the ME-SFI [ME] control unit (N3/10).

The Electronic Stability Program control unit (N30/4) transmits information about the status of the service brake via the chassis FlexRay (Flex E), the powertrain control unit (N127) and the drive train CAN to the ME-SFI [ME] control unit.

Start 

The ME-SFI [ME] control unit reads in the following signals for starting:

The ME-SFI [ME] control unit actuates the following assembly parts to start the Engine:

The ME-SFI [ME] control unit coordinates the injection and firing order during starting based on the signals from the crankshaft Hall sensor and the intake camshaft and exhaust camshaft Hall sensors.

Start begin 

By actuating the KEYLESS-GO start/stop button, the ME-SFI [ME] control unit receives the "circuit 50 signal" from the electronic ignition lock control unit via the suspension FlexRay, powertrain control unit and drive CAN.

Vehicles except code B01 (48V Technology) 

The ME-SFI [ME] control unit actuates the circuit 50 starter relay on both sides with a ground signal. The power contact of the starter circuit 50 relay closes and the solenoid switch of the starter is supplied at "circuit 50" with a voltage from "circuit 30".

Vehicles with code B01 (48V Technology) 

The ME-SFI [ME] control unit transmits the request to start the Engine via the Engine CAN to the powertrain control unit. The powertrain control unit evaluates all relevant variables and transmits the request to start the Engine via the hybrid CAN to the starter-alternator.

When the KEYLESS-GO start/stop button is operated, the ME-SFI [ME] control unit requests the starting procedure from the powertrain control unit.

When the starting procedure is initiated, the shutting off of "circuit 50" will have no further influence on the starting procedure. The start process can only be canceled if circuit 15 is switched off.

IMPORTANT Engine 264.9 in Model 205, 253

except code B01 (48V Technology)

At the positive pole of the on-board electrical system battery (G1), the voltage dip limiter (R62) is installed. It is connected to the circuit 50 relay for starter via circuit 50. On starting the Engine, the voltage dip limiter engages the integrated series resistor. This reduces the starter's power consumption when the Engine is cranked. The voltage drop that is perceptible to the vehicle occupants when starting the Engine is reduced. If the on-board electrical system voltage drops too much due to the high power consumption of the starter, the voltage dip limiter switches the series resistor off again.

Ending start 

Starter control is carried out automatically by the ME-SFI [ME] control unit (touch start). This means that once a starting procedure is initiated, deactivating "circuit 50" no longer has an influence on the starting procedure.

Vehicles except code B01 (48V Technology) 

When Engine cranking speed has reached 400 to 700 RPM, or after a starting time of 5 to 40 s (dependent on coolant temperature), the ME-SFI [ME] control unit interrupts the negative activation of the circuit 50 starter relay and thus terminates the starting procedure.

Vehicles with code B01 (48V Technology) 

The ME-SFI [ME] control unit transmits the Engine speed via the Engine CAN to the powertrain control unit. On reaching the Engine cranking speed of 400 to 700 RPM or a starting time of approx. 5 to 40 s (depending on the coolant temperature), the powertrain control unit stops the starting procedure and transmits the "Engine running" signal to the DC/DC converter control unit via the suspension FlexRay, electronic ignition lock control unit and interior CAN.

The start process can be broken off through renewed actuation of the KEYLESS-GO start-stop button.

  Electrical function schematic for starting   PE07.10-P-2701-97FBI 
  Overview of system components for gasoline injection and ignition system with direct injection   GF07.70-P-9998MRS