Low Pressure Fuel Pump Operational Test
- Connect jumper wire from pump ground terminal to a clean underbody ground and connect another jumper from pump feed terminal to alternator output terminal connection.
- If pump operates, test is okay. Go to LOW PRESSURE PUMP GROUND CIRCUIT TEST . If pump does not operate, replace low pressure pump.