Quick Test: Notes
The QUICK TEST diagnostic procedure is a functional test of the EEC-IV system. It consist of 4 basic test steps. These basic steps must be carefully followed in sequence, otherwise a misdiagnosis, or replacement of non-faulty components may result.
Perform QUICK TEST as follows: perform PREPARATION and EQUIPMENT HOOK-UP steps, KEY ON/ENGINE OFF SELF-TEST , TIMING CHECK , ENGINE RUNNING SELF-TEST , and CONTINUOUS SELF-TEST. After all tests, servicing, or repairs have been completed, repeat QUICK TEST to ensure EEC-IV system works properly.
- The KEY ON/ENGINE OFF SELF-TEST is a static check of EEC-IV system inputs and outputs. The TIMING CHECK verifies the ability of the system to compute and maintain a fixed spark timing during SELF-TEST.
- The ENGINE RUNNING SELF-TEST is a dynamic system check with the engine under actual operating conditions and at normal operating temperature. The CONTINUOUS SELF-TEST checks the sensor inputs for opens and shorts while the vehicle is in operation.
- The KEY ON/ENGINE OFF and ENGINE RUNNING SELF-TESTS are intended to detect faults present at the time of testing, not intermittent faults. Intermittent faults are detected by CONTINUOUS SELF-TEST.