Fuel Pressure Regulator
Disconnect vacuum line at the pressure regulator. Connect a hand-operated vacuum pump to the regulator fitting and apply 18 in. Hg vacuum. If the reading does not remain at 18 in. Hg vacuum, replace the pressure regulator, See Fig 1 .