Low Pressure Fuel Pump
- Connect jumper wire from pump ground terminal to chassis ground and connect another jumper from pump feed terminal to alternator output terminal connection. See Figure .
- If pump operates, Go to LOW PRESSURE PUMP GROUND CIRCUIT test. If not, replace low pressure pump.