Relay To EEC Continuity
Using an ohmmeter, check for continuity between relay terminal No. 85 and EEC pin No. 22. If there is continuity, pump circuit is okay. If no continuity, repair open in circuit.
Using an ohmmeter, check for continuity between relay terminal No. 85 and EEC pin No. 22. If there is continuity, pump circuit is okay. If no continuity, repair open in circuit.