Quick Test: Notes
The QUICK TEST diagnostic procedure is a functional test of the EEC-IV system, consisting of basic test steps. These basic steps must be carefully followed in sequence, otherwise a misdiagnosis, or replacement of non-faulty components may result.
- VISUAL CHECK AND PREPARATION is checking for obvious faults and defects and preparing vehicle for testing.
- EQUIPMENT HOOK-UP ensures the proper equipment is used and is properly operating prior to testing.
- KEY ON/ENGINE OFF SELF-TEST is a static check of EEC-IV system inputs and outputs.
- TIMING CHECK verifies the ability of the system to compute and maintain a fixed spark timing during SELF-TEST.
- ENGINE RUNNING SELF-TEST is a dynamic system check with the engine under actual operating conditions and at normal operating temperature.
- CONTINUOUS SELF-TEST checks the sensor inputs for opens and shorts while the vehicle is in operation.
- KEY ON/ENGINE OFF and ENGINE RUNNING SELF-TEST are intended to detect faults present at the time of testing, not intermittent faults. Intermittent faults are detected by CONTINUOUS SELF-TEST .