Special Tools
When testing the power supply of the EMS2000, the DISplus multimeter function or a hand held multimeter may be used. It is best to make the checks at the EMS2000 connection as this method tests the wiring harness. The correct V-Adapter Cables must be used to ensure the pin connectors and the harness will not be damaged.
V-Adapter Cables for the EMS2000 are:
- 40 Pin V-Adapter Cable P/N 12 7 240
- 81 Pin V-Adapter Cable P/N 12 7 250
- Breakout Box (BOB) P/N 61 4 390
- Breakout box (BOB) P/N 61 4 380
CAUTION:
When installing the BOB and V-Adapter Cables to the EMS2000 make sure the ignition has been switched off for at least 5 minutes or remove the Main Relay.