High Altitude
Disconnect high altitude compensator hose harness at compensator. Connect hand vacuum pump to one of compensator hose connections. Attempt to create vacuum. If vacuum can be created, replace compensator. If vacuum is not created, compensator is working properly. Reconnect hose harness to compensator.