Component Testing: Turbocharged
- On Mirage and Starion models, connect a 1/2" O.D. hose to secondary air cleaner intake hose. On Cordia and Tredia models, disconnect air supply hose at air cleaner.
- On all models, start engine and warm to 104-140°F (40-60°C). There should be suction at hose at idle. When engine temperature reaches 158°F (70°C) or more, there should be no suction. Accelerate engine to 4000 RPM and as engine is decelerating, there should be suction at air hose.
- If these conditions are met, secondary air supply system is good. Replace reed valve if exhaust gases blow out of air hose.