Power Transistor (Fuel Injected Models)
- Disconnect power transistor connectors. Using a DVOM, connect positive ohmmeter lead to terminal No. 2 and negative lead to terminal No. 3. See Fig 5
. Ensure there is no continuity.
- Using a 1.5-volt dry cell battery, connect positive end of 1.5-volt battery to power transistor terminal No. 1 and negative end to terminal No. 2. DVOM should now read continuity at power transistor terminals No. 2 and No. 3. If DVOM does not respond as described, replace power transistor.
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.