Sensor Operating Range Charts
NOTE:
For connector and terminal identification see WIRING DIAGRAMS
article. AIRFLOW METER VOLTAGE TEST
| Condition |
Volts |
| 700-3000 RPM |
2.7-3.2 |
BAROMETRIC PRESSURE SENSOR VOLTAGE TEST
| psi (kg/cm2
) |
Volts |
| 2.9 (20) |
0.79 |
| 6.9 (49) |
1.84 |
| 15 (103) |
4.0 |
COOLANT TEMPERATURE SENSOR RESISTANCE TEST
| Temperature °F (°C) |
Ohms |
| 32 (0) |
5900 |
| 68 (20) |
2500 |
| 104 (40) |
1100 |
| 176 (80) |
300 |
INTAKE AIR TEMP SENSOR RESISTANCE
| Temperature °F (°C) |
Ohms |
| 32 (0) |
6600-5400 |
| 68 (20) |
2970-2300 |
| 176 (80) |
310-430 |
MOTOR POSITION SENSOR RESISTANCE TEST
| Condition |
Ohms |
| Connector Unplugged |
4000-6000 |
| Apply 6 volts |
Resistance Changes Smoothly |
OXYGEN SENSOR VOLTAGE TEST
| Condition |
Volts |
| Lean |
0.1 |
| Rich |
1.0 |
THROTTLE POSITION SENSOR (TPS) RESISTANCE TEST
| Position |
Terminal
(Ground-Output) |
Ohms |
| Closed |
1-3 |
3500-6500 |
| Open |
1-2 |
500-(3500-6500) |
VEHICLE SPEED SENSOR VOLTAGE TEST
| Reed Switch |
Volts |
| On |
1 or Less |
| Off |
5 |