System Test
- Disconnect Red-striped vacuum hose between throttle body and purge control solenoid valve at throttle body. Connect a hand-held vacuum pump to disconnected vacuum hose. Plug nipple on throttle body where vacuum hose was removed.
- On 3.0L engines, with engine temperature at 104°F or 40°C (140°F or 60°C on 1.5L and 2.4L engines) or less and engine idling, apply 7.3 in. Hg vacuum should hold. Raise engine speed to 3000 RPM and again apply 7.3 in. Hg vacuum should hold.
- On 3.0L engines, with engine coolant temperature at 176°F or 80°C (158°F or 70°C on 1.5L and 2.4L engines) or more and engine idling, apply 7.3 in. Hg vacuum should hold. Turn engine off. Start engine and within 3 minutes of starting engine, apply vacuum. Vacuum should bleed down.
- With engine running for more than 3 minutes after starting, raise engine speed to 3000 RPM and apply 7.3 in. Hg. Vacuum should hold momentarily and then bleed down.