Service Specifications
Fastener Tightening Specifications
| ITEM | STANDARD VALUE | LIMIT | |
|---|---|---|---|
| Generator | |||
| Regulated voltage (Ambient temperature at voltage regulator) | -20°C (-4°F) | 14.2 - 15.4 | - |
| 20°C (68°F) | 13.9 - 14.9 | - | |
| 60°C (140°F) | 13.4 - 14.5 | - | |
| 80°C (176°F) | 13.1 - 14.5 | - | |
| Generator output line voltage drop (at 30A) V | - | Maximum 0.3 | |
| Output current | - | 70% of normal output current | |
| Field coil resistance Ω | Approximately 2 - 5 | - | |
| Brush protrusion length mm (in) | - | Minimum 2 (0.08) | |
| Starter motor | |||
| Free running characteristics | Terminal voltage V | 11 | - |
| Current A | 95 | - | |
| Speed r/min | 2,500 or more | - | |
| Pinion gap mm (in) | 0.5 - 2.0 (0.02 - 0.07) | - | |
| Commutator run-out mm (in) | 0.05 (0.002) | Minimum 0.1 (0.004) | |
| Commutator diameter mm (in) | 29.4(1.16) | Minimum 28.8 (1.13) | |
| Undercut depth mm (in) | 0.5 (0.02) | Minimum 0.2 (0.008) | |
| Ignition parts | |||
| Ignition secondary coil resistance at 20°C (68°F) kΩ | 8.5 - 11.5 | - | |
| Spark plug gap mm (in) | 0.6 - 0.7 (0.024 - 0.028) | 0.85 (0.033) | |
| Spark plug cable resistance kΩ | - | Maximum 19 | |