Troubleshooting Guide

The charging system troubleshooting guide is shown in illustration.

  1. STEP 1. 

    Q: Is the battery in good condition? (Refer to ON-VEHICLE SERVICE .)

    YES  : Go to Step 2.

    NO  : Charge or replace the battery.

  2. STEP 2. 
  3. Q: Is the generator drive belt in good condition? Refer to DRIVE BELT (FOR GENERATOR, A/C COMPRESSOR AND WATER PUMP) ].

    YES  : Go to Step 3.

    NO  : Adjust the belt tension or replace the belt.

  4. STEP 3. 

    Q: Does the generator malfunction light come on when the ignition switch is turned on? 

    YES  : Go to Step 4.

    NO  : Check the ignition switch. (Refer to INSPECTION ).

    Check the generator malfunction light and its related circuits.

    Check the generator Refer to INSPECTION  .

  5. STEP 4. 

    Q: Does the generator malfunction light go out after starting the engine? 

    YES  : Go to Step 5.

    NO  : Check the generator Refer to INSPECTION  .

  6. STEP 5. 

    Q: Is an oscilloscope available? 

    YES  : Go to Step  6.

    NO  : Go to Step  7.

  7. STEP 6. 

    Q: Does the oscilloscope show a normal wave pattern? (Refer to VOLTAGE REGULATION TABLE 

    YES  : Go to Step 7.

    NO  : Check the generator Refer to INSPECTION  .

  8. STEP 7. 
    • Engine: 2, 500 r/min
    • Headlight: ON (high beam)
    • Voltage between generator terminal B and the positive battery terminal

      OK: 0.5 V or less

    • Voltage between the negative battery terminal and generator body

    OK: 0.5 V or less

    Q: Are the generator output line and ground line in good condition? 

    YES  : Go to Step 8.

    NO  : Check the generator output line and ground line.

  9. STEP 8. 

    Q: Is the output current normal? (Refer to OUTPUT CURRENT TEST  .)

    YES  : Go to Step 9.

    NO  : Check the generator [Refer to INSPECTION  .

  10. STEP 9. 

    Q: Is the regulated voltage normal? (Refer to REGULATED VOLTAGE TEST  .)

    YES  : Go to Step 10.

    NO  : Check the generator Refer to INSPECTION  .

  11. STEP 10. 

Q: Is the voltage drop in the generator output line normal? 

YES  : Generator is normal. Check other systems.

NO  : Check the output line.