Service Specifications
| Item | Standard value | Limit | |
|---|---|---|---|
| Regulated voltage (Ambient temperature at voltage regulator) | -20°C (-4°F) | 14.2 - 15.4 | - |
| 20°C (68°F) | 13.9 - 14.9 | - | |
| 60°C (140°F) | 13.4 - 14.6 | - | |
| 80°C (176°F) | 13.1 - 14.5 | - | |
| Generator output line voltage drop (at 30 A) V | - | Maximum 0.3 | |
| Output current | - | 70 % of normal output current | |
| Field coil resistance Ω | Approximately 2 - 5 | - | |
| Brush protrusion length mm (in) | - | Minimum 2 (0.08) | |