Inspection Procedure 1: Throttle Valve will not Fully Open or Close: Diagnosis
- STEP 1. Using scan tool MB991958, read the MFI system diagnostic trouble code (DTC). CAUTION: To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991958.
- Connect scan tool MB991958 to the data link connector (Refer to DIAGNOSTIC FUNCTION ) <2.0L ENGINE> or (Refer to DIAGNOSTIC FUNCTION ) <2.4L ENGINE>.
- Turn the ignition switch to the "ON" position.
- Set scan tool MB991958 to check for MFI system DTC (Refer to DIAGNOSTIC FUNCTION ) <2.0L ENGINE> or (Refer to DIAGNOSTIC FUNCTION ) <2.4L ENGINE>.
Q: Is any DTC set?
YES : Repair the MFI system (Refer to DIAGNOSTIC TROUBLE CODE CHART ) <2.0L ENGINE> or (Refer to DIAGNOSTIC TROUBLE CODE CHART ) <2.4L ENGINE>. Then go to Step 2.
NO : Go to Step 2.
- STEP 2. Check the symptom.
Q: Does the throttle valve fully open and close?
YES : The procedure is complete.
NO : Return to Step 1.