Engine Stall: Accelerating
- Connect inductive timing light to spark plug wire and check for weakness in flash.
- Ensure spark plug wires are within allowable resistance values.
- Check for spark using spark tester.
- Ensure engine has adequate compression.
- Enter self-diagnostic Mode II and monitor fuel metering system operation.
- Disconnect exhaust gas sensor and monitor change in driveability. If it improves, replace sensor. If not, go to 5.
- For Crank Angle Sensor & Airflow Meter: Enter self-diagnostic Mode III and retrieve codes. If vehicle will not start, crank engine before entering self-diagnostic Mode III.
- For Crank Angle Sensor & Airflow Meter: Enter self-diagnostic Mode V and monitor real-time diagnostic setting of fault codes. Perform appropriate code chart in TESTS W/CODES article.