Engine Controls - Sensor Operating Range Charts: Introduction
Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.
NOTE:
All voltage tests should be performed with a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance, unless stated otherwise in test procedure. To identify ECU terminals, see appropriate wiring diagram in WIRING DIAGRAMS
article in the ENGINE PERFORMANCE Section.
AIRFLOW METER VOLTAGE TEST
| Application |
Terminal No. |
Volts |
| Maxima |
27 |
1.0-2.0 |
| NX & Sentra |
| 1.6L |
16 |
.8-3.0 |
| 2.0L |
16 |
1.3-2.1 |
| Pathfinder, Pickup, Stanza & 240SX |
16 |
1.0-3.0 |
| 300ZX |
27 |
.8-1.6 |
AIR TEMPERATURE SENSOR VOLTAGE TEST
| Temperature °F (°C) |
Volts |
| Pickup (2.4L) |
| 68 (20) |
2.4 |
| 176 (80) |
.3 |
| Stanza |
| 68 (20) |
1.0-1.5 |
| 176 (80) |
.3 |
COOLANT TEMPERATURE SENSOR RESISTANCE TEST
| Temperature °F (°C) |
Ohms |
| 68 (20) |
2100-2900 |
| 176 (80) |
300-330 |
EXHAUST GAS TEMPERATURE SENSOR VOLTAGE TEST
| Application |
Terminal No. |
Volts w/EGR Closed |
Volts w/EGR Open |
| Maxima |
39 |
1.0 Or More |
0-1.0 |
| NX & Sentra |
| 1.6L |
8 |
2.0-4.0 |
0-2.0 |
| 2.0L |
8 |
4.5 Or Less |
0-1.0 |
| Pathfinder & Pickup |
| 3.0L |
8 |
1.0-2.0 |
0-1.0 |
| Pickup |
| 2.4L |
8 |
3.0-4.0 |
0-3.0 |
| Stanza |
8 |
1.0-2.0 |
0-1.0 |
| 240SX |
8 |
4.5 Or Less |
0-1.0 |
| 300ZX |
39 |
4.5 Or Less |
0-1.0 |
FUEL TEMPERATURE SENSOR VOLTAGE TEST
| Application |
Terminal No. |
Volts |
| 300ZX |
36 |
0-5.0 |
DETONATION (KNOCK) SENSOR VOLTAGE TEST
| Application |
Terminal No. |
Volts |
| Maxima |
23 |
3.0-4.0 |
| Pathfinder & Pickup (3.0L) |
27 |
2.5 |
| 300ZX |
23 |
2.5 |
NEUTRAL/INHIBITOR SWITCH VOLTAGE TEST
| Application |
Terminal No. |
Volts In Park/Neutral |
Volts In All Other Positions |
| Maxima |
44 |
Battery |
0 |
| NX & Sentra |
35 |
0 |
Battery |
| Pathfinder, Pickup Stanza & 240SX |
35 |
0 |
6.0-7.0 |
| 300ZX |
44 |
0 |
8.0-9.0 |
OXYGEN SENSOR VOLTAGE TEST
| Condition |
Volts |
| Lean |
.1 |
| Rich |
1.0 |
THROTTLE POSITION SENSOR VOLTAGE TEST
| Application |
Terminal No. |
Volts |
| Maxima |
38 |
.5-4.2 |
| NX & Sentra |
20 |
.4-5.0 |
| Pathfinder & Pickup |
20 |
.5-4.0 |
| Stanza |
20 |
.4-4.0 |
| 240SX |
20 |
.4-5.0 |
| 300ZX |
38 |
.4-4.0 |
VEHICLE SPEED SENSOR CONTINUITY TEST
| Application |
Terminal No. |
Specification |
| Except Maxima & 300ZX |
32 |
|
| Maxima & 300ZX |
53 |
|