LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Nissan-Datsun >> 1992 >> Sentra SE-R >> Repair and Diagnosis >> Electrical >> Starter >> Testing >> On-Vehicle Testing >> No Load Test
April 5, 2026: LEMON Manuals is launched! Read the announcement.

No Load Test

Connect starter in series with a 12-volt battery, a voltmeter and a 1000-amp ammeter. Compare readings with STARTER NO LOAD SPECIFICATIONS  table.

STARTER NO LOAD SPECIFICATIONS (HITACHI)

Application Maximum Amps Minimum RPM
S114-486 100 3900
S114-534 90 2950
S114-630 60 7000
S114-701A 90 2950
S114-701B 90 2950
STARTER NO LOAD SPECIFICATIONS (MITSUBISHI)

Application Maximum Amps Minimum RPM
M1T72985 75 4000
M1T72088 75 4000
M2T53883 100 2900
M3T37783 60 6500
STARTER IDENTIFICATION DIRECTORY

Application Fig. No.
Hitachi
S114-486 2
S114-630 5
S114-701A (1) 6
Mitsubishi
M1T72088 4
M1T72985 3
M2T53883 1
M3T37783 7
(1) S114-701B starter for NX and Sentra is similar.