CKP Sensor
- If a fault is present in CKP sensor, Code 11 may be set in ECM memory. If Code 11 is set, perform appropriate CODE 11 (CKP SENSOR) in TESTS W/CODES article.
- To test CKP sensor, remove distributor. Leave wiring harness connected. Using a voltmeter, connect negative lead to ground and alternately connect positive lead to terminal "A" (120-degree signal) and terminal "B" (1-degree signal). See Figure.
- Measure voltages while rotating distributor by hand. Voltage should fluctuate 0-5 volts. If either voltage signal does not fluctuate 0-5 volts, check harness for short or open circuit. If no problems are found, replace CKP sensor.