Trunk Lid Operation
Power is supplied at all times:
- Through 10A fuse [No. 6, located in the fuse block (J/B)]
- To trunk lid opener actuator terminal +.
When a TRUNK OPEN signal is sent with key OFF (ignition key removed from key cylinder) from keyfob, ground is supplied:
- To trunk lid opener actuator terminal -
- Through smart entrance control unit terminal 12.
Then power and ground are supplied, trunk lid opener actuator opens trunk lid.