Check Fuel Level Sensor Unit and Fuel Pump
Check resistance between terminals 2 and 5.
CONNECTOR TERMINAL RESISTANCE SPECIFICATION
| Terminals |
Float position mm (in) |
Resistance value (Ω) (Approx.) |
| 2 |
5 |
|
Full |
145.9 (5.74) |
5 |
|
Empty |
14 (0.55) |
81.5 |
Courtesy of NISSAN MOTOR CO., U.S.A.