EVAP Canister
Check EVAP canister as follows:
- Block port (B) .
- Blow air into port (A) and confirm that it flows freely out of port (C) .
- Release blocked port (B) .
- Apply vacuum pressure to port (B) and confirm that vacuum pressure exists at the ports (A) and (C) .
- Block port (A) and (B) .
- Apply pressure to port (C) and check that there is no leakage.