One Window Is Inoperative From Individual Switch, Operates From Master Switch: Aurora
Disconnect master switch connector. Disconnect right rear window switch connector. Turn ignition switch to RUN position. Connect a fused jumper between Brown wire and Dark Blue wire terminals (window lock-out) at master switch connector. Connect test light between ground and Dark Blue wire terminal at right rear window switch connector. If test light is on, check for poor connection at master switch. If connection is okay, replace master switch. If test light is off, repair open in Dark Blue wire between master switch and inoperative window switch.