One Window (Except Left Front) Inoperative From Master & Individual Switch, All Others Operate
- Turn ignition switch to RUN position. Using a test light, backprobe between 2 terminals at inoperative window motor connector. While observing test light, press inoperative window switch (individual switch) to UP and DOWN positions. If test light is not on, go to next step. If test light is on, check for poor connection at inoperative window motor. If connection is okay, replace inoperative window motor.
- Check continuity of Dark Blue and Brown wires between inoperative window motor connector and corresponding individual switch connector. If continuity exists, go to next step. If continuity does not exist, repair open wire in question.
- Using a test light, backprobe between the appropriate UP and DOWN terminals on master switch for inoperative window motor. Press master switch for inoperative window to UP and DOWN positions. If test light is not on, replace master switch. If test light is on, check continuity of circuits between inoperative individual switch connector and master switch connector. See WIRING DIAGRAMS . If circuits are okay replace individual switch in question.