LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Oldsmobile >> 1998 >> Intrigue Base >> Repair and Diagnosis >> Electrical >> Charging Systems >> Description
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Charging Systems: Description

The CS130 and CS144 (Charging System) generators have a high amperage output. The 130 or 144 designation is the outside diameter of the stator laminations, measured in millimeters. CS series generators include a delta stator, rectifier bridge, and rotor with slip rings and brushes. A built-in regulator incorporates fault detection circuitry. See Fig 1 or Fig 2 . A conventional pulley and external fan are used to cool slip ring end frame, rectifier bridge and regulator. On CS130D, D indicates Dual Internal Fan (DIF) design. Information is not available on this generator. Testing is identical.

The generator operates with 4 wire connections and a ground path through the mounting bracket. The first wire connection is the BAT (output) terminal. This terminal must be connected to the battery during operation. The second wire connection is connected from generator terminal "L" internal regulator lamp driver to PCM. This circuit monitors and controls generator operation. The PCM controls indicator light function. The third wire connection is connected from generator terminal "L" to PCM. The PCM also monitors this circuit. The fourth wire is connected from generator terminal "S" to ALT SENSE fuse (10 amp) in underhood junction block. This provides internal regulator with an external voltage reading. If this circuit is interrupted, regulator will default to internal voltage reading for control.

Regulated voltage varies with temperature. System limits voltage by controlling rotor field current while field current is on. Regulator switches rotor field current on and off at a fixed frequency of 400 cycles per second to help control radio noise. By varying overall on/off time, correct average field current for proper system voltage control is obtained. At high speeds, with lower electrical loads, on-time may be 10 percent. At low speeds, with higher electrical loads, on-time may be as much as 90 percent. Refer to the GENERATOR USAGE/AMP OUTPUT RATING  table.

Fig 1: Charging System Wiring Schematic CS130 Series
G95D35165Courtesy of GENERAL MOTORS CORP.
Fig 2: Charging System Wiring Schematic CS144 Series
G95E35166Courtesy of GENERAL MOTORS CORP.
GENERATOR USAGE/AMP OUTPUT RATING

Application Generator Rated Output
Standard CS130D 105
High Output CS144 140